AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual

SlimTech
SYSTEM
www.aaocare.com
HKS909 User ManualAAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 1

THEORY

SlimTeck is an advanced, noninvasive beauty device that is used for reducing cellulite, eliminating stubborn fat, and improving sagging and wrinkled skin. It has two technologies combined into one: a vacuum roller massager and radiofrequency. Our multi-functional device is suitable for full-body treatments. Enjoy the relaxing massage effects while achieving incredible results. The slimline design makes it ideal for salons and spas.

BENEFITS

  1. Circumferential reduction
  2. Cellulite reduction
  3. Increased blood circulation
  4. Relief of minor muscle aches and spasms
  5. Wrinkle reduction
  6. Skin lifting and tightening
  7. Soothing skin Massage

 MECHANICAL EFFECTS ON THE SKIN

The mechanical rollers knead the skin inward so that the LED and RF waves can penetrate deeper into the skin.

  1. Rolling the skin upward facilitates a better suction effect from the vacuum.
  2. The repeated kneading of the skin improves lymphatic drainage and reduces cellulite.

When all edges of the vacuum are in full contact with the skin, a seal is made, creating a gentle suction.

  1. Negative pressure dilates the blood vessels, increasing blood floods in the local area.
  2. Vacuum levels are:
    Smooth applicator – up to 380 millibars
    Contour applicator – up to 440 millibars

IMPORTANT SAFETY INSTRUCTION
Read all instructions before using this device; save these instructions for future reference.
This manual contains important safety symbols and instructions. Pay attention to these symbols and follow all instructions provided.

AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 2 This symbol indicates instructions for use; consult accompanying documents.

AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 3 General Warning or Caution
This symbol indicates personal injury or damage to the equipment is possible.

AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 4 Electric Shock Symbol
This symbol indicates a voltage hazard; any mishandling could result in irreparable damage to the equipment, personal injury, or death.
.AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 5 Keep Dry-Symbol
This symbol indicates the device cannot be used outdoors or where it can become wet.

Semtech INFORMATION

  1. PartsAAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 6
  2. Contol PanelAAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 7
  3. How to change the filter – Replace the sponge filters every 3 to 6 monthsAAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 8

How to clean the roller

AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 9

PRE-TREATMENT PREPARATION

  1. Exfoliate the skin before treatment. Make sure skin is clean and dry (no perfume or lotion). It is also advised to remove any jewelry that may be in the treatment area.
  2. Hair may impair the movement of the applicator, be pulled out during treatment, or overheat the treatment area. Removing hair before treatment is advised.
  3. Avoid anticoagulants, such as aspirin, throughout the treatment. Anticoagulants increase the possibility of bruising.
  4. Before the first treatment session, it is important to establish a baseline. Take note of your weight, photograph yourself and measure the circumference of the treatment area. Re-weigh yourself before each subsequent session to monitor your results throughout the treatment program.
  5.  Cellulite or contour may change characteristics when you are lying down, so mark the treatment areas when standing (use a white or yellow marker).
  6. Make sure the RF (Radio Frequency) electrodes are clean and intact and verify that the rollers move smoothly.
  7. Make sure that the filters are clean and inserted correctly. Filter replacement is needed every 3-6 months, depending on use. Use tweezers to pull out used filters.
  8. Make sure that the filters are clean and correctly inserted (replace them if not). Replace the sponge filters every 3 to 6 months depending on use. Use tweezers to pull used filters out. Be careful with the rubber O ring when changing the filter.

TREATMENT PROCEDURE

Assist the treatment by slightly stretching curved or loose skin with your free hand. Push or pull the skin to or from the side towards the applicator. You may also improve contact by placing a rolled towel under the treatment area and pushing it up. Adjust heat accordingly.
It is recommended to treat the front thigh and abdomen from a supine position and the back thigh, buttocks, and the back from a prone position. Very large hips and inner thighs may be treated while lying on your side with a bent knee.
If the anatomical area is extremely large divide it into two areas, such as half-abdomen, half-thigh, or half-buttock. It is easier to reach and maintain the desired heat in areas that are not too large. However, if the area is too small it may heat up the treatment area superficially.

  1. Abdomen and Waist
    Use the navel as your midpoint, measure 5 points that are 1 ½ inch and 2 1/2 inches from the navel, and record. You also can adjust the measurement point according to client height differences – see P1AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 10
    Using the navel as the midpoint, draw one vertical line and one horizontal line to divide the abdomen into four parts. After completing treatment on one section, go to the next section. Repeat treatment within all 4 sections until each section of the abdomen is warm – see P2.
    It is important to observe the skin for redness. Adjust thermal power and repeat on treatment sections. Makes sure the applicator touches all of your skin in the targeted treatment area.
    Note: Fat layers around the stomach and ribs are thin, so make sure the applicator contacts those areas fully.
  2.  Back Area
    There are two methods for the back area:
    1. The linear suction operation
    2. Figure-8 Shape twist suction operationAAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 11
  3. Thigh
    1. Apply a linear suction method starting from the outer upper thigh, moving from up to down, and from left to right.
    2. The inside of the thigh is a sensitive area, If these In reddens do not be alarmed; this is normal. Adjust heat accordingly.AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 12
  4.  Arm
    1. Apply the linear suction method from the inner arm to the outer arm.
    2. Inside of the arm is sensitive and the temperature can rise rapidly. Adjust heat accordingly.AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 13
  5. Buttocks
    1. Apply the linear suction method.
    2. Use one hand to pull the skin up and the other hand to hold the HP. Move from bottom to upper buttocks and repeat several times.
    3. Slowly increase suction strength to your comfort level. Start from the inside of the upper thigh, moving toward the outer thigh.
    4. Continuous treatment should be applied from the bottom to upper buttocks with the highest comfortable suction strength.
    AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 14Use back and forth motions on a strip of skin. The applicator width is -30 cm long. Move to the next zone after 5 minutes. Come back to the first zone and treat again after completion of the second zone. Retain the heat by passing over both previous strips in cross-hatched motions (zig-zag or circles). Continue the process until you have covered the entire area. Your skin may feel warm for 30 minutes or longer after treatment.
    1. Constant contact is essential for good results. Always maintain complete contact between the machine and the skin.
    2. For smaller zones, such as the navel area, treat twice and ensure a 5-minute interval is kept between treatments.
    3. After the treatment, the treated area may show temporary signs of erythema and slight edema.
    Body parts Vacuum Power RF Power Timer(Minutes)
    Abdomen and waist 2-3 2-3 20-30
    Back area 2-3 3-4 20-30
    Thigh 3 1-2 10-20
    Arm 3 1-2 10-20
    Buttock 1-2 4-5 20-30

EXPECTATIONS

  1. There will be an improvement in cellulite appearance and in circumferential reduction, but not necessarily the complete elimination of cellulite. Results are based on specific individuals.
  2. The rate of response to the treatment, and the number of treatment sessions required will vary among clients and will depend on the clinical and physiological condition at the start of the treatment regimen. Some clients respond better than others.
  3. The treatment results are temporary and one maintenance treatment session every 2-3 months is essential to sustain results.
  4. A healthy lifestyle (diet and exercise) may help to obtain better results but is not essential. However, weight gain may have a negative effect on the results.

Radiofrequency is a separate operating system You should turn off the radio frequency after every treatment.

ELECTROMAGNETIC EMISSIONS GUIDANCE

CAUTION: This device meets the electromagnetic emissions requirements per IEC 60601-1-3. The device was not tested for immunity to electromagnetic disturbances. If the user observes unusual device behavior, particularly if such behavior is intermittent and associated with nearby use of radio or TV transmitters, cell phones, or electro-surgical equipment, this could be an indication of electromagnetic interference. If such behavior occurs, the user should try to move the interfering equipment further from this device.
WARNING: The use of accessories other than those specified or provided with the device could result in increased electromagnetic emissions and result in improper operation.AAOCARE HKS909 Slim-Tech Radio Frequency Vacuum Massage Roller User Manual  & troubleshooting 15

Register your device today at aaocare.com and Receive our one-year extended warranty.
The warranty will cover manufacturing defects and we will repair or replace your device at no cost.

AAOCARE.COM
22732 Granite Way
Suite B
Laguna Hills CA 92653
[email protected]

References